Temperature Ethernet Sensor of T-Line series by Comet Sytem enables monitoring of temerature via net with transmission of alarms and show history of values. Sensor can generate emails with alerts and data files. Sensor can be connected to various SCADA system by different manufacturers and also to Comet System's Data Base software.
| Ethernet interface
10Base-T/100Base-TX Ethernet interface via standard RJ45 connector. Manual IP address setting or DHCP. |
|
| WWW server
Measured values accessible via powerful embedded web server. Mobile Web view. Sensor configuration via web. Web Sensor allows user to customize the design of web pages. |
|
| History values memory
1000 Measured values are stored into history memory according to selected time interval. |
|
| History graphs
Graphs with history values are accessible via web pages. Modern HTML5 canvas graphic component allows using graphs from thousands of devices Tablets and smartphones supported. All modern web browsers are supported - Firefox, Opera, Chrome or Internet Explorer 9. |
|
| History export to CSV
History values can be exported directly to CSV file (supported by Microsoft Excel). |
|
| Email
Warning emails sent when alarm is on. Emails also sent when alarm is off. SMTP authentication supported, (not SSL). Emails with CSV file attachment can be sent at selected intervals. |
|
| Modbus TCP protocol
Modbus TCP protocol communication supported. Two Modbus clients can be connected to device at one moment. |
|
| Actual values via XML
XML protocol for actual measured values reading. This protocol is suitable for device integration into 3rd party SCADA systems. |
|
| SNMP protocol
SNMP protocol enables reading of actual measured values, alarm status, alarm parameters and last 1000 measured values from history table. MIB tables with OID description are available. |
|
| SNMP Trap
SNMP Trap for IT infrastructure. Web Sensor allows sending Traps to selected Trap receiver server. Traps are sent in case of alarm or at error states. |
|
| SOAP protocol
Web Sensor allows to send currently measured values via SOAP v1.1 protocol. The device sends values in XML format to the web server. The advantage of this protocol is that communication is initialized by the device side. No port forwarding is necessary. |
|
| Syslog protocol
Syslog protocol for IT infrastructure monitoring systems. Web Sensors allow sending text message to selected Syslog server. Messages are sent in case of alarm or at error states like unable to send email, unable to deliver SOAP message, etc. |
|
| SNTP protocol - time synchronization
Time synchronization with SNTP server. |